Insulating company with phenol and oil contamination

Spills of non-polymerisated phenolicformaldehyde resulted in the phenol pollution of groundwater. The area around the storage tanks was contaminated with diesel fuel and heating oil.

  Project description


Client: Insulating company with phenol and oil contamination

Technology:
Soil bioremediation in-situ with bioaugmentation, nutrient addition through injection wells
infiltration galleries, active soil aeration system
groundwater pump and treat system, with activated carbon adsorption

Project Status: Completed

Media (quantity in m³):
Soil (in-situ): 3000m³ Groundwater: 3000m³

Contaminants:
diesel, heating, and lubrication oil, phenol

Project Manager: József Varga, Judit Tóth

Date of operation: 1994-1996

Cleanup goals (=contaminant concentration after treatment)
Residual petrol hydrocarbons in soil: 500 ppm, in groundwater <0.1 mg/l
Phenol in groundwater 0.05 mg/l

Contaminant concentration before treatment:
petrol hydrocarbon contaminated soil treating in-situ 500-5000 ppm
in groundwater dissolved diesel hydrocarbon 1-3 mg/l, phenol 0.5-2 mg/l

( <<-- back one chapter )
Remediation

Remediation of soil and groundwater. INTERGEO’ s environmental engineers and scientists have completed more than 2000 soil and groundwater remediation projects in Europe and overseas.( <-- back one page )
Pharmaceutical production: Contamination with organic solvents

In the course of pharmaceutical production the soil and groundwater was contaminated with organic solvents in the surroundings of tanks and the factory building.( Index )
Remediation

Remediation of soil and groundwater. INTERGEO’ s environmental engineers and scientists have completed more than 2000 soil and groundwater remediation projects in Europe and overseas.( next page --> )
Remedial work at filling stations throughout Hungary

The failure of the old technical systems had resulted in contamination of soil and groundwater.( next chapter --> )
Analyses

Environmental laboratory and analyses with mobile laboratory bus.German version
Dämmstoff-Fabrik mit Phenol- und Ölkontaminationen
 Intergeo Consulting   
 Impressum   
 News   
 Languages   
 Branch offices   
 References   
 Consulting   
 Site investigation   
 Remediation   
 Analyses   
 Applications   
 Technologies   
 Pollutants   
 Water Technology   
 Seawater desalination   
 Remediation 
 References 1-10 
 References 11-20 
 References 21-20 
 Car station 
 Fuel tank site 
 Oil spill 
 Landfill 
 Pharmaceutics 
 Insulating company 
 Filling station 
 Gas motor mill 
 Railways 
 Railway brakeyard 
 Military area 
 Industrial site 
 EC program 
 Fertilizer facility