Gasoline station with a contamination of volatile hydrocarbonsDue to construction work at this gasoline station a contamination of volatile hydrocarbons was found in the unsaturated soil zone.
|
| Project description |
A contamination of volatile hydrocarbons was found in the vicinity of pipes during a changing of gasoline pipes at this gasoline station. The remediation was performed with in-situ measures with soil vapour extraction. To speed up the working process on site, horizontal perforated pipes were installed and connected to 2 soil vapour extraction units with activated carbon filters. In the following 7 months the remediation was finished successfully and in accordance with the local authorities.
Client: Oil industry
Location: Gasoline station Austria
Project manager: Mag. Michael Reiter
Contaminated area: 150 m² until 2m below the surface between the gasoline pipes.
Date of operation: 11/2000 – 07/2001
Kind of used technologies: Soil vapour extraction, infiltration of atmospheric air
Max. concentration of contaminant at beginning of remediation: 4700 mg/kg hydrocarbons (BTX)
Clean up goals: According to Austrian standards for soilgas and soil.