Public bus garage with subsurface contaminationGarage with refueling and maintenance facilities. A contamination was detected in the vicinity of the fuel handling points.
|
| PROJECT DESCRIPTION |
The site was a garage for public transport buses with refueling and maintenance facilities. Extensive subsurface contamination was detected, mainly in the vicinity of fuel handling points. The diesel oil contamination was concentrated above the saturated zone.
Technology
Soil excavation and in-situ bioremediation with bioaugmentation, groundwater pumping and skimming.
Project Status: Completed
Media (quantity in m³):
Soil (ex-situ): 1,500
Soil (in-situ): 10,500
Groundwater: 3,000
Contaminants: Diesel oil, lubrication oil
Client: Budapest Public Transport Company
Project Manager: József Varga, Judit Tóth
Completed Project Information
Date of Operation: 1995-1999 Cleanup Goals: Residual contaminant in soil <1,000 ppm, in groundwater <0.1 mg/l
Contaminant concentration before treatment:
Excavated soil ranged from 10,000 ppm to 25,000 ppm,
in-situ treated diesel and lubrication oil contamination in soil 1000-15000 ppm
in groundwater free phase in film, dissolved contamination 1-5 mg/l.
Contaminant concentration after treatment: less than cleanup goal.